Raked wall layout calculator

Describe a rising wall by two end heights or by a starting height and pitch, in Pro² for iPhone.

In the app · English

Tools → Raked walls → Raked wall from two heights

Tools → Raked walls → Raked wall from pitch angle

Download on the App Store

For iPhone · iOS 18 or later

Free to download.

See the worked example
Studs below a rakeHorizontal plan / run
The dashed line is the horizontal bottom-plate run between the wall ends. End heights are vertical from the same bottom datum; top positions follow the sloping line. The example uses metres and degrees and does not specify stud cuts.Illustration; not to scale.

What to measure

For setting out the geometry of a wall beneath a straight rake. Both modes describe the same wall using different measurements available on site.

Wall run and end geometry
Horizontal bottom-plate length, starting height, and either opposite height or pitch angle.
Plates and stud spacing
Bottom/top plate thicknesses and spacing measured along the bottom plate.

Choose the right setup

Two Heights derives pitch from the height difference divided by horizontal run. Pitch mode derives the far height from run × tan(angle).

Read the result

  • Pitch or far-end height, sloping top-plate length, and a numbered setting-out table.
  • Bottom-plate and top-plate positions plus the app’s stud-length column; check the actual joint geometry before making a cut list.

A worked example

Top-line geometry for a wall rising by 1 m over a 4 m horizontal run. The example does not specify stud cuts.

Inputs and results
QuantityValue
Starting height; far height2.4 m; 3.4 m
Horizontal run; stud spacing4 m; 0.6 m
Angle; top-plate length14.036°; 4.123 m
Bottom positions, including end0; 0.6; 1.2; 1.8; 2.4; 3.0; 3.6; 4.0 m

How the numbers fit together

Angle = atan((far height − start height)/run). Top length = √(run² + height difference²). Pitch mode with the unrounded angle returns the same far height. The last interval is shorter when the chosen spacing does not divide the run.

Units, allowances and limits

Metric and imperial lengths are supported; pitch is entered in degrees. Top-plate positions are distances along the slope, while bottom positions are horizontal. Do not interchange the two columns.

Treat the diagram as a geometric reference. Plate thickness, bearing details, cut angles and how each stud meets the top plate must be resolved in the working drawing. The example above verifies the wall envelope only.

On the job

Which mode should I start with?

Use two heights when both ends have been measured. Use pitch when the slope is specified and you know the starting height.

Why is the top-plate mark further along?

It is measured along a longer sloping line, not as a horizontal projection.

Which mode should I start with?
Use two heights when both ends have been measured. Use pitch when the slope is specified and you know the starting height.
Why is the top-plate mark further along?
It is measured along a longer sloping line, not as a horizontal projection.